TSA30 Electronic Temperature Switch and Transmitter

  • Pt100 measuring system
  • up to 2 switch points
  • analogue output 4...20 mA or 0...10 V
  • rotatable 320° display and electrical connection
  • menu navigation refers to VDMA standard
  • IO-Link communication interface
  • max. pressure: 200 bar
  • Measuring ranges:
    0...100 °C or -30...+130 °C

More informations

Integrated in a stainless steel protection tube is a tempera­ture-dependent electrical resistor (Pt100). This changes its ohmic resistance depending on the media temperature.

Up to two transistor outputs are available as limit value con­trol.

In the version with built-in transmitter, the resistance change is converted into a 4...20 mA analogue current signal or a 0...10 V voltage signal and made available electrically. Different measuring ranges, process connections, sealing materials and probe lengths can be selected.

Typical applications

The resistance thermometers are very well suited for use in general mechanical engineering, apparatus engineering, plant engineering, container and pipeline construction, as well the chemical industry, process engineering and the food industry, where they are preferably used for recording the temperature in liquid and gaseous media.

Due to their on-site display, they are also ideally suited for installation at process-relevant points for visual control.