Magnetisch-Induktiver Kompakt-Durchflussmesser DM01 4 images

PDF Information

For Further Information

E-mail to This email address is being protected from spambots. You need JavaScript enabled to view it.

DM01A Compact magnetic inductive flowmeter

  • for conductive liquids
  • independent of viscosity, density, pressure, or temperature
  • maintenance free
  • high accuracy
  • practically no pressure loss
  • measuring value range up to 1:50
  • smallest dimensions
  • frequency and analogue output
  • measuring tube of PVDF, electrodes of st.st. 1.4435, Hastelloy
  • max. pressure: 10 bar (20 °C), max. temperature: 60 °C
  • min. conductivity: 20 µS/cm
  • ranges:
    0,05...2 up to 5...250 l/min

More informations >

Magnetisch-Induktiver Kompakt Durchflussmesser -Ganzmetallausführung- DM04 4 images

PDF Information

For Further Information

E-mail to This email address is being protected from spambots. You need JavaScript enabled to view it.

DM04 Magnetic inductive compact flowmeter -all metal version-

  • for electrically conductive liquids
  • independent of viscosity, density, pressure or temperature of the medium
  • practically no pressure drop
  • high measurement accuracy:
    +/- 1,5 % v. MW, +/- 0,3 % v. ME
  • maintenance free
  • max. pressure 16 bar, max. temperature 90 °C
  • measuring range:
    0,5...30 l/min to 5...250 l/min

More informations >

DM12 Magnetisch-Induktiver Durchflussmesser für große Nennweiten 4 images

PDF Information

For Further Information

E-mail to This email address is being protected from spambots. You need JavaScript enabled to view it.

DM12 Magnetic inductive flowmeter for large nominal sizes

  • for electrically conductive liquids
  • DN 15 up to DN 200
  • independent of viscosity, density, pressure or temperature of the medium
  • practically no pressure drop
  • high measurement accuracy, large measuring span
  • robust housing, maintenance free
  • compact- or remote version
  • Pmax: 40 bar, Tmax: 160 °C
  • range:
    0,2...6 m³/h -  34...1131 m³/h water

More informations >

DU06 Ultraschall Durchflussmesser mit Anzeige 6 images

PDF Information

For Further Information

E-mail to This email address is being protected from spambots. You need JavaScript enabled to view it.

DU06 / DW-S Ultrasonic flowmeter and counter with local indication

  • independent of viscosity, density, pressure, negligible pressure drop
  • materials: brass, stainless steel
  • max. pressure: 25 bar, max. temperature: 100 °C
  • output:
    4..20 mA, 0..10 V, or frequency
    2 switching outputs
  • accuracy: +/- 2% FS
  • ranges:
    0,5..80 l/min, G 1/2
    1..180 l/min, G 1
    8..1000 l/min, G 2

More informations >

DTH04, Kalorimetrischer Durchflusstransmitter 4 images

PDF Information

For Further Information

E-mail to This email address is being protected from spambots. You need JavaScript enabled to view it.

DTH04 Calorimetric flow sensor in 12 mm housing

  • for liquids
  • fast reaction
  • no moving parts, pipe diameter independent
  • high temperature gradient, negligible pressure drop
  • PN 25, max temperature: 100 °C
  • available with calibrated T-piece or integrated inlet and outlet pipes
  • universal mounting by cutting edge connection
  • high measuring range:
    2...150 cm/s and 3...300 cm/s

More informations >

Kalorimetrischer Kompakt-Durchflusswächter für Luft -Schaltausgang- DTL04 3 images

PDF Information

For Further Information

E-mail to This email address is being protected from spambots. You need JavaScript enabled to view it.

DTL04 Calorimetric flow sensor for air -switching output-

  • for flow control of air
  • relay or transistor output
  • insignificant pressure loss
  • no moving parts
  • independent of nominal sizes, pressure and temperature
  • max. pressure: 10 bar, max. temperature: 80 °C
  • range:
    0,1...15 m/s

More informations >

Kalorimetrischer Kompakt-Durchflussmesser für Luft -Analogausgang- DTL06 2 images

PDF Information

For Further Information

E-mail to This email address is being protected from spambots. You need JavaScript enabled to view it.

DTL06 Calorimetric flow sensor for air -analoque output-

  • flow measurment of air
  • analogue output: 0...10 V
  • insignificant pressure drop
  • no moving parts
  • uaffected by duct diameter, pressure and temperature
  • max. pressure: 10 bar, max. temperature: 70 °C
  • range:
    0,1...30 m/s

More informations >

Kalorimetrischer Kompakt-Durchflussmesser für Luft -Analog, DTL08 2 images

PDF Information

For Further Information

E-mail to This email address is being protected from spambots. You need JavaScript enabled to view it.

DTL08 Compact calorimetric flowmeter for air

  • for measurement and monitoring of velocity or volume as well as temperature of air flows
  • no moving parts, therefore insensitive to dirt
  • sensor from nickel plated brass.
  • max. pressure 10 bar, max. temperature 80 °C
  • output signals:
    transistor switch output and relay output
    analog output for flow (4...20 mA and 0...10 V)
    analog output for temperature (0...10 V)
  • ranges:
    0...1 to 0...30 m/s

More informations >

DB03 Thermischer Massendurchflussmesser, Verbrauchssensor für Luft und Gase 4 images

PDF Information

For Further Information

E-mail to This email address is being protected from spambots. You need JavaScript enabled to view it.

DB03 Thermal Flow and Consumption Sensor for Compressed Air and Gases

  • low cost series
  • easy installation, high flexibility, no straight inlet section due to integrated flow conditioner necessary
  • version Eco: for air and N2
    version Pro: for different gases
  • data logger and pressure measurement optional
  • smartphone Android app for wireless configuration and measuring value indication
  • process connection: G 1/4 female up to G1 female
  • max. pressure: 10 bar, max. temperature: 50 °C
  • measuring ranges:
    0,5...50 l/min up to 35...3500 l/min

More informations >

DB04A Thermischer Massedurchflussmesser für Gase 7 images

PDF Information

For Further Information

E-mail to This email address is being protected from spambots. You need JavaScript enabled to view it.

DB04A Thermal mass flowmeter for gases, battery powered

  • pressure and temperature independent
  • measurement indication of flow and total consumption (counter integrated)
  • compact design, no need for straight pipe runs
  • touchdisplay for intuitive navigation
  • needle valve and switch output as option
  • high measuring accuracy
  • max. pressure: 11 bar, max. temperature: 50 °C
  • battery operated – no external power supply needed
  • ranges:
    0,001-0,05 Nl/min ... 9-450 Nl/min air

More informations >

DB05 Thermischer Massendurchflussmesser und -regler für Gase 7 images

PDF Information

For Further Information

E-mail to This email address is being protected from spambots. You need JavaScript enabled to view it.

DB05 Thermal mass flowmeter and controller for gases

  • independent of pressure or temperature variations of the medium
  • compact design, no straight pipe runs in front of the meter necessary
  • materials: aluminium or stainless steel
  • max. pressure: up to 11 bar, max. temperature: up to 50 °C
  • accuracy: +/- 1.5 % FS (standard) or
    +/- 0.3 % FS & +/- 0,5 % MV (enhanced accuracy)
  • turn-down ratio 1:50 optional 1:100
  • analogue output and control input: 4...20 mA, other analogue signals optionally
  • serial interface
  • supply voltage: 24 VDC
  • ranges:
    005-25 Nml/min ... 9-450 Nl/min gas

More informations >

Thermischer Durchflussmesser und -zähler, mit und ohne Anzeige 5 images

PDF Information

For Further Information

E-mail to This email address is being protected from spambots. You need JavaScript enabled to view it.

DB50 Thermal mass flowmeter and counter for compressed air and non-aggressive gases

  • insertion model
  • available for DN 15 to DN 1000 pipe sizes
  • max. pressure. 50 bar, max. temperature: 110 °C
  • local LCD-display for flow rate, total or temperature optional
  • output signals: 4...20 mA for flow rate, total or temperature
  • for compressed air and non-aggressive gases
  • zero balance possible at instrument
  • ranges:
    0...50 m/s, 0...92,7m/s, 0...185 m/s, 2...224 m/s
    148 m³/h… 191.524 m³/h air

More informations >

Kompakter-Thermischer Masse-Durchflussmesser DB51 6 images

PDF Information

For Further Information

E-mail to This email address is being protected from spambots. You need JavaScript enabled to view it.

DB51 Compact mass thermal flowmeter and counter for gases

  • integrated inlet and outlet pipes for high level of accuracy
  • removable sensor system for easy maintenance and cleaning
  • available for 1/4“ to 2“ pipe sizes and DN 15 to DN 80 flanges
  • max. pressure: 40 bar, max. temperature: 80 °C
  • local LCD-display for flow rate, total or temperature
  • output signals: 4...20 mA for flow rate, pulses for totalization
  • for compressed air and non-aggressive gases
  • zero balance possible at instrument
  • ranges:
    0,8...105 l/h to 7...2840 m³/h

More informations >