Logo The Experts for Process Instrumentation
Flow Level Temperature Pressure Accessories
Products
News
Contact
Catalogue
About us
Home
Product Locator:
Click here for advanced search
Sight Flow Indicators
Variable Area Flowmeters
Paddle Type Flowmeters
And Switches
Paddle Wheel, Turbine,
And Gear Wheel Flowmeters
Electronic Flowmeters
DTH01 - Compact calorimetric flow switch for liquids
To monitor the flow of liquid media.
Without moving parts, therefore insensitive to dirt.
Wetted parts stainless steel.
Max. pressure: 100 bar.
Max. temperature: 70 °C.

Range:
Flow velocities from 1 to 150 cm/s.
Output signal: PNP or NPN transistor switch output.
Trend indication for flow velocitiy.
Supply voltage 24 VDC.
Available with optional temperature switch point.

DTH01
DTH02 - Modular calorimetric flow switch for liquids
To monitor the flow of liquid media.
Without moving parts, therefore insensitive to dirt.
Wetted parts stainless steel.
Process connection: G 1/4 male, G 1/2 male or Tri-Clamp.
Max. pressure: 100 bar.
Max. temperature: 70 °C.

Range:
Flow velocities from 1 to 150 cm/s.
Output signal: PNP or NPN transistor switch output or SPDT relay 5A.
Trend trend indication for flow velocity.
Supply voltage: 24 VDC or 230 VAC.
Available with optional temperature switch point.

DTH02
PDF Information
Operating Manual
PDF Information
Operating Manual
DTH08 - Calorimetric flowmeter for low flows
For measurement of flow and temperature of liquid media
Without moving parts, therefore insensitive to pollution
Wetted parts stainless steel
Max. pressure 10 bar
Max. temperature 70 °C

Measuring range: 0,01...2 bis 0,05...10 l/min
Output signals:
Transistor switch output
Analogue output
Frequency output
(every output signal may be configured either for flow or temperature)

DTH08
DTL08 - Compact calorimetric flowmeter for air
for measurement and monitoring of velocity or volume as well as temperature of air flows
no moving parts, therefore insensitive to dirt
sensor from nickel plated brass.
max. pressure 10 bar
max. temperature 80 °C

measuring ranges: 0...1 bis 0...30 m/s
output signals:
transistor switch output and relay output
analog output for flow (4...20 mA and 0...10 V)
analog output for temperature (0...10 V)

DTL08
PDF Information
Technical Specifications
for further information mail to info@pkp.de

DB04 - Battery operated thermal mass flowmeter for gases
Independent of pressure or temperature variations of the medium.
Compact design, no straight pipe runs in front of the meter necessary.
Materials: aluminium or stainless steel.
max. pressure: up to 10 bar.
max. temperature: up to 50 °C.

Ranges:
0.004-0.2 Nl/min ... 4-200 Nl/min gas
Supply voltage: battery operated or 24 VDC.
Indication: LCD for flow rate and bargraph.
Optionally: integrated control valve, limit switch or totaliser.

DB04
DB05 - Thermal mass flowmeter and controller for gases
Independent of pressure or temperature variations of the medium.
Compact design, no straight pipe runs in front of the meter necessary.
Materials: aluminium or stainless steel.
max. pressure: up to 10 bar.
max. temperature: up to 50 °C.

Ranges:
0-25 ml/min ... 0-200 l/min gas.
Accuracy: +/- 1.5% FS (standard) or +/- 0.5% FS (enhanced accuracy).
Turn-down ratio 30 or 100 : 1.
Analogue output and control input: 4...20 mA, other analogue signals optionally.
Serial interface.
Supply voltage: 24 VDC.

DB05
PDF Information
Technical Specifications
Operating Manual
PDF Information
Technical Specifications
Operating Manual
DB08 - Thermal mass flowmeter for gases with stainless steel sensor system
Independent of pressure or temperature variations of the medium.
Compact design, no straight pipe runs in front of the meter necessary.
Materials: aluminium or stainless steel.
max. pressure: up to 10 bar.
max. temperature: up to 70 °C.

Ranges:
0.005-0.1 Nl/min ... 375-7500 Nl/min gas

Supply voltage: 24 VDC.
Optionally: LCD indication for flow rate or flow total.

DB08
DB09 - Thermal mass flowmeter and controller for gases with stainless steel sensor system
Independent of pressure or temperature variations of the medium.
Compact design, no straight pipe runs in front of the meter necessary.
Materials: aluminium or stainless steel.
max. pressure: up to 10 bar.
max. temperature: up to 70 °C.

Ranges:
0.005-0.1 Nl/min ... 50-1000 Nl/min gas.
Integrated proportional control valve.
Supply voltage: 24 VDC.
Optionally: LCD indication for flow rate or flow total.

DB09
PDF Information
Technical Specifications
Operating Manual
PDF Information
Technical Specifications
Operating Manual
DB40 - Thermal mass flowmeter and counter for gasses - insertion version for large pipe diameters
practically independent of pressure and temperature variations
of the medium
robust construction
materials: stainless steel and glass
max. pressure: up to 50 bar
max. temperature: -30...+110 °C

mounting: by means of weld-on boss G 1/2 onto pipe
for pipe sizes from DN25 (1") up to DN600 (24")
max. flow velocities:
92,7 m/s, 185 m/s oder 224 m/s
supply voltage: 24 VDC
LCD-indication for flow rate and flow total optionally
output signals:
analog output 4...20 mA for flow rate,
pule output for flow total

DB40
DB41 - Thermal mass flowmeter and counter for gasses with integrated up- and downstream flow conditioners
practically independent of pressure and temperature variations of the medium
robust construction, with integrated up- and downstrean straight pipe runs
material: stainless steel and glass
max. pressure: up to 16 bar
max. temperature: -30...+80 °C

process connections:
1/4" ...1 1/2" G or NPT
measuring ranges:
0,8-90 Nl/min ... 1,8-400 Nm³/h Gas

supply voltage: 24 VDC
LCD-indication for flow rate and flow total
output signals:
analog output 4...20 mA for flow rate,
pulse output for flow total

DB41
PDF Information
Technical Specifications
Operating Manual
PDF Information
Technical Specifications
Operating Manual
DU04 - Precision ultrasonic flowmeter for liquids
independent of viscosity, pressure, and density
practically no pressure loss
materials: brass / stainless steel (in preparation)
max. Druck: 200 psi / 14 bar

measuring ranges:
0.18-15 ... 4.96-400 GPM
0,72-60 ... 18-1500 l/min
bidirectional, with optional status signal for determination of flow direction
output signal:
4...20 mA, 2 wire
accuracy: +/- 0,75% f.s.

DU04
DM01 - Compact magnetic inductive flowmeter
Independent of viscosity, density, pressure, or temperature.
Practically no pressure loss.
Smallest dimensions.
Wetted parts: Delrin / stainless steel.
Max. pressure: 6 bar.

Ranges:
1-5 ... 10-200 l/min.
Min. conductivity: 20 µS/cm.
Ouput signal:
Flow proportional frequency output.
Accuracy: +/- 1,5% of actual measured value.

DM01
PDF Information
Technical Specifications
Operating Manual
PDF Information
Technical Specifications
Operating Manual
DM10 - Magnetic inductive flow meter
Suitable for all conductive media.
For pipe diameters from 1" to 24".
Compact version or separate sensor and electronic available.
Cladding: polyurethane, hard rubber or PTFE

Process connections: flanges to DIN or ANSI, PN10...PN40.
Microprocessor controlled electronic with self-diagosis. Indication of flow rate and total, analogue output 4-20 mA, programmable pulse, alarm or status output.

DM10
PDF Information
Technical Specifications
Top of Page