Products/Page

DM01 Compact magnetic inductive flowmeter

  • for conductive liquids
  • independent of viscosity, density, pressure, or temperature
  • practically no pressure loss
  • smallest dimensions
  • measuring tube and electrodes of st.st. 1.4435,
    process connection of POM or PVDF
  • max. pressure: 10 bar (20 °C)
  • ranges NEW!:
    0,05-2 ... 5-250 l/min
  • min. conductivity: 20 µS/cm
  • ouput signal: Flow proportional frequency output
  • accuracy: +/- 1 % of actual measured value
DM04 Magnetic Inductive Flowmeter

For Further Information

E-mail to This email address is being protected from spambots. You need JavaScript enabled to view it.

DM04 Magnetic Inductive Flowmeter

  • for electrically conductive liquids
  • independent of viscosity, density, pressure or temperature of the medium
  • practically no pressure drop
  • high measurement accuracy:
    +/- 1,5 % v. MW, +/- 0,3 % v. ME
  • measuring ranges: 0,5-30 l/min ... 5-250 l/min
  • maintenance free

DM08 Magnetic-Inductive-Flowmeter

  • for electrically conductive liquids
  • DN 15 up to DN 200
  • measuring range 0-6 m³/h ... 28-1130 m³/h water
  •  PN 10, PN 16, PN 25, PN 40
  • -20...+180°C
  • independent of viscosity, density, pressure or temperature of the medium
  • maintenance free
  • practically no pressure drop
  • high measurement accuracy
  • Compact- or separate version
  • robust housing
  • Fast signal processing with a 16-bit microcontroller

DW03 Vortex Flowmeter and Switch

  • for low viscosity liquids
  • compact dimensions
  • totalisatorfunction
  • optional with valve
  • rotatable, three coloured display
  • available with built-on display or separated for panel mounting
  • pipe sizes from G 3/8 to G 1
  • measuring ranges:
    0,5...4 l/min to 10...100 l/min

DTH04 Calorimetric flowmeter flowswitch in 12 mm housing

  • for liquids
  • fast reaction
  • no moving parts
  • pipe diameter independent
  • high temperature gradient
  • negligible pressure drop
  • high measuring range, reliable measurement from 2...150 cm/s and from 3...300 cm/s
  • available with calibrated T-piece or integrated inlet and outlet pipes
  • universal mounting by cutting edge connection
DTH01 Compact calorimetric flow switch for liquids

PDF Information

DTH01 Compact calorimetric flow switch for liquids

To monitor the flow of liquid media.
Without moving parts, therefore insensitive to dirt.
Wetted parts stainless steel.
Max. pressure: 100 bar.
Max. temperature: 70 °C.

Range:
Flow velocities from 1 to 150 cm/s.

Output signal: PNP or NPN transistor switch output.
Trend indication for flow velocitiy.
Supply voltage 24 VDC.
Available with optional temperature switch point.

DTH08 Calorimetric flowmeter for low flows

For measurement of flow and temperature of liquid media
Without moving parts, therefore insensitive to pollution
Wetted parts stainless steel
Max. pressure 10 bar
Max. temperature 70 °C

Measuring range: 0,01...2 bis 0,05...10 l/min

Output signals:
Transistor switch output
Analogue output
Frequency output
(every output signal may be configured either for flow or temperature)

DTL08 Compact calorimetric flowmeter for air

for measurement and monitoring of velocity or volume as well as temperature of air flows
no moving parts, therefore insensitive to dirt
sensor from nickel plated brass.
max. pressure 10 bar
max. temperature 80 °C

measuring ranges: 0...1 bis 0...30 m/s

output signals:
transistor switch output and relay output
analog output for flow (4...20 mA and 0...10 V)
analog output for temperature (0...10 V)

DB04A Thermal Mass Flowmeter for Gases - without Auxiliary Power

For Further Information

E-mail to This email address is being protected from spambots. You need JavaScript enabled to view it.

DB04A Thermal Mass Flowmeter for Gases - without Auxiliary Power

  • pressure and temperature independent
  • measurement idication of flow and total consumption (counter integrated)
  • measuring ranges: 0,001-0,05 Nl/min ... 9-450 Nl/min air
  • compact design, no need for straight pipe runs
  • touchdisplay for intuitive navigation
  • needle valve and switch output as option
  • high measuring accuracy
  • battery operated – no external power supply needed

DB05 Thermal mass flowmeter and controller for gases

  • independent of pressure or temperature variations of the medium
  • compact design, no straight pipe runs in front of the meter necessary
  • materials: aluminium or stainless steel
  • max. pressure: up to 11 bar
  • max. temperature: up to 50 °C
  • measuring ranges:
    005-25 Nml/min ... 9-450 Nl/min gas
  • accuracy: +/- 1.5 % FS (standard) or
    +/- 0.3 % FS & +/- 0,5 % MV (enhanced accuracy)
  • turn-down ratio 1:50 optional 1:100
  • analogue output and control input: 4...20 mA, other analogue signals optionally
  • serial interface
  • supply voltage: 24 VDC
DB50 Thermal Mass Flowmeter and Counter for Compressed Air and Non-Aggressive Gases

For Further Information

E-mail to This email address is being protected from spambots. You need JavaScript enabled to view it.

DB50 Thermal Mass Flowmeter and Counter for Compressed Air and Non-Aggressive Gases

  • insertion model
  • available for DN 25 (1”) to DN 600 (24”) pipe sizes
  • for flow velocities: 0...92,7 m/s, 0...185 m/s or 0...224 m/s
  • local LCD-display for flow rate and total optional
  • output signals: 4...20 mA for flow rate and total
  • for compressed air and non-aggressive gases
  • zero balance possible at instrument
DB51 Compact Thermal Mass Flowmeter and Couner for Compressed Air and Non-Aggressive Gases

For Further Information

E-mail to This email address is being protected from spambots. You need JavaScript enabled to view it.

DB51 Compact Thermal Mass Flowmeter and Couner for Compressed Air and Non-Aggressive Gases

  • integrated inlet and outlet pipes for high level of accuracy
  • removable sensor system for easy maintenance and cleaning
  • available for 1/4“ to 2“ pipe sizes
  • measuring ranges 0,8...80 Nl/min to 1,8...1100 Nm³/h
  • local LCD-display for flow rate and total
  • output signals: 4...20 mA for flow rate, pulses for totalization
  • for compressed air and non-aggressive gases
  • zero balance possible at instrument

DU06 Ultrasonic flowmeter andcounter with local indication

independent of viscosity, density, pressure, negligible pressure drop
materials: brass, stainless steel
max. pressure: 25 bar

Measuring ranges:
0,5..80 l/min, G 1/2
1..180 l/min, G 1
8..1000 l/min, G 2

Output:
4..20 mA, 0..10 V, or frequency
2 switching outputs
accuracy: +/- 2% FS

Copyright MAXXmarketing Webdesigner GmbH